Condo NotesRevisionas of Saturday, 28 June 2025 at 01:27 UTC

Maintenance Requests

HOA Rules and Regulations

This is the latest version.

HVAC

  • Lennox Package Rooftop Unit on Northmost End of roof.
  • Serial 5608G11033, manufactured 2008 (that’s what the “08” in the number means)
  • Model TGA036S2-PKG (the “03” means it’s a 3-ton unit)

Any maintenance personnel will need roof access. The disconnect box is marked on the outside with the unit number.

June 13, 2025

A capacitor was busted and needed replacemen (they typically last about 10-15 years). The compressor was very hot and needed to cool down. Worked with Lozier Heating and Cooling for a satisfactory resolution. Highly recommended. The replacement will outlive the unit and Lozier provides a guarantee.

Lighting

Fixture Bulb Notes
Bathroom Square BP35G9/830 “G9 LED” 3000K
Corridor Square BP35G9/830 “G9 LED” 3000K
Clothes Closet F32T8/735, 48in, 3000K
Utility Closet F32T8/735, 48in, 3000K
Bathroom Sink F21T5/830, 34in, 3000K
Kitchen Hanging Light A15, 40W/5W (if LED), 3000K
Kitchen Flood Lights BPMR16/GU10, 2700K. Original were 6W. Using 4W.
Laundry Room Square CF13DS/E/841 “G9 LED” “13W 841” means 4100K. “827” means 2700K. Mount says it takes 2GX7 bulbs, 13W max.

Floor Plan

1,248ft²

E5W Floorplan

Old Website

Other Stuff

Blinds