Testing New Hard Drives Revision as of Wednesday, 26 June 2024 at 10:57 UTC
Find out the disks on the system
cat /var/run/dmesg.boot
Run the short test in the background1.
smartctl -t short /dev/ada0
Then run a conveyance test (for any damage during shipping)
smartctl -t conveyance /dev/ada0
Then check for bad
blocks23.
badblocks -ws /dev/ada0
Then run a long test4.
smartctl -t long /dev/ada0
The -a
flag shows you everything about the drives
smartctl -a /dev/ada0
including the time remaining for the tests
Self-test execution status: ( 249) Self-test routine in progress...
90% of test remaining.
and the time it would take to run the tests:
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 529) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
To see the results after the tests have run
smartctl -l selftest /dev/ada0